AI-Generated Summary NVIDIA Mission Control connects IT and OT systems to coordinate leak responses and monitor compute and facility conditions in liquid-cooled AI factories. The software provides configurable MQTT integration with building management systems, leak action policies mapped to the physical data center hierarchy, rack management commands for monitoring electrical, cooling, and leak detection systems, and observability integration with Prometheus and Grafana dashboards. Leak action policies define automated responses based on leak location and affected device count, with preconfigured templates for device, rack, row, room, and building scopes that coordinate actions across BMCs, the cluster manager, and the BMS. Rack mode commands such as electricaloverview, liquidcoolingoverview, leakdetectionoverview, and leakinfo bring together data from liquid-cooled infrastructure to monitor conditions and support incident investigation. Next Steps Watch the NVIDIA Mission Control demo video to see the BMS integration in action. Review the Mission Control Integration with Building Management System Guide for prerequisites and implementation steps. Managing AI infrastructure such as NVIDIA Vera Rubin NVL72 requires coordinated operation of compute, power, and cooling systems. In liquid-cooled AI factories, a leak response may require operational teams to stop workloads, isolate affected nodes, and control power circuits and cooling valves. AI factory operations span two domains that have historically operated separately. Information technology (IT) teams manage compute resources, workload orchestration, and application performance. Operational technology (OT) teams handle physical building systems—power distribution, cooling infrastructure, and environmental safety. This post explains how NVIDIA Mission Control connects IT and OT systems to coordinate leak responses and monitor compute and facility conditions. IT and OT convergence in liquid-cooled environments Liquid cooling creates interdependencies between IT and OT systems that require coordinated responses. When a leak sensor triggers, IT systems may need to stop workloads and isolate affected compute nodes, while a building management system (BMS) manages power circuits and cooling valves. The response sequence depends on the configured policies and facility requirements. The challenge is coordinating these actions across systems quickly and reliably. Figure 1 shows the leak detection components around the racks and coolant distribution unit. Liquid-cooled systems can handle higher thermal loads per rack than air-cooled equivalents, supporting higher rack power densities. Teams integrating AI systems with building infrastructure must consider six operational requirements: Protocol compatibility Safety and regulatory compliance Response times Unified visibility into compute health and facility status Scalability Coordination across operational teams Addressing these requirements helps when coordinating compliance activities, improving response times, and sharing operational data. Custom integrations that support real-time communication and actionable insights can be difficult to maintain as deployments grow. Flexible configuration for enterprise AI factories When building liquid-cooled NVIDIA DGX SuperPOD clusters for production, the NVIDIA team tested tighter integration with building management systems by adding connections and policies to the cluster management software. A common integration framework provides standardized interfaces for IT and OT systems, supports communication across vendor ecosystems, and provides configurable policies for different organizations’ operational requirements. These integrations must also preserve the security boundaries required by both domains. NVIDIA Mission Control, a software stack for AI factory operations and orchestration, provides this integration for enterprises deploying NVIDIA GB200 NVL72 and NVIDIA GB300 NVL72 systems. Standardized integration helps teams reuse operational knowledge about liquid-cooled infrastructure instead of developing each connection independently. NVIDIA Mission Control provides four configuration and monitoring capabilities: Configurable MQTT integration with building management systems Configurable leak action policies Rack management commands for monitoring electrical, cooling, and leak detection systems Observability integration with Prometheus and dashboards for monitoring compute and facility metrics Teams can configure these capabilities through NVIDIA Base Command Manager, the cluster management software in NVIDIA Mission Control. Figure 2 shows how MQTT connects NVIDIA Mission Control and the BMS. Configurable MQTT for BMS integration NVIDIA Mission Control integrates with building management systems through MQTT, a lightweight messaging protocol used in industrial internet of things (IoT) and building automation systems. The NVIDIA Base Command Manager command-line interface, cmsh, supports MQTT broker connections, authentication configuration, and selection of facility data streams for AI factory operations. The following commands display the existing MQTT role configuration, including certificate paths and configured servers: [a08-u04-p01-bcm-01]% configurationoverlay [a08-u04-p01-bcm-01->configurationoverlay]% use mqtt [a08-u04-p01-bcm-01->configurationoverlay[mqtt]]% roles [a08-u04-p01-bcm-01->configurationoverlay[mqtt]->roles]% use mqtt [a08-u04-p01-bcm-01->configurationoverlay[mqtt]->roles[mqtt]]% show Parameter Value -------------------------------- --------------------------------------------------------------------------------- Name mqtt Revision Type MQTTRole Add services yes Servers <1 in submode> CA certificate path /cm/local/apps/cmd/pythoncm/lib/python3.12/site-packages/pythoncm/etc/cacert.pem Private key path /cm/local/apps/cmd/cm-mqtt/etc/mqtt.key Certificate path /cm/local/apps/cmd/cm-mqtt/etc/mqtt.pem Write named pipe path /var/spool/cmd/mqtt.pipe The following commands list the configured MQTT servers and display the connection settings for mqtt-bcm-client: [a08-u04-p01-bcm-01->configurationoverlay[mqtt]->roles[mqtt]% servers [a08-u04-p01-bcm-01->configurationoverlay[mqtt]->roles[mqtt]->servers]% ls Server (key) Port Disabled ---------------- ---------- ---------- mqtt-bcm-client 1883 no [a08-u04-p01-bcm-01->configurationoverlay[mqtt]->roles[mqtt]->servers]% use mqtt-bcm-client [a08-u04-p01-bcm-01->configurationoverlay[mqtt]->roles[mqtt]->servers[mqtt-bcm-client]]% show Parameter Value -------------------------------- ------------------------------------------------ Revision Server Port 1883 Topic BCM/# Disabled no Username BCM Password ******** Transport tcp Protocol v3.1.1 Certificate required yes Check hostname yes Configurable leak action policies A leak detected in a single compute tray requires a different response from a leak affecting an entire row of racks. NVIDIA Mission Control uses leak action policies to define responses based on the leak location and the number of affected systems. The policy structure follows the physical data center hierarchy: building, room, row, rack, and device. For example, teams can configure a policy to isolate and power down a tray when one device reports a leak. A broader policy could shut down power and cooling to a row and notify the BMS to close facility-level valves when three or more racks in that row detect leaks. The system executes the configured responses automatically. Figure 3 shows how policies map to the physical hierarchy. NVIDIA Mission Control includes preconfigured policies for device, rack, row, room, and building scenarios. Teams can use these templates as provided or customize them to meet operational requirements. The following commands list the available policies: [a08-u04-p01-bcm-01->partition[base]]% leakactionpolicies [a08-u04-p01-bcm-01->partition[base]->leakactionpolicies]% ls Name (key) Rules ------------------------ ---------------------------------- Default building policy Building, Device, Rack, Room, Row Default device policy Device Default rack policy Device, Rack Default room policy Device, Rack, Room, Row Default row policy Device, Rack, Row The following commands display the rules in the default building policy: [a08-u04-p01-bcm-01->partition[base]->leakactionpolicies]% use "Default building policy" [a08-u04-p01-bcm-01->partition[base]->leakactionpolicies[Default building policy]]% rules [a08-u04-p01-bcm-01->partition[base]->leakactionpolicies[Default building policy]->rules]% ls Name (key) Scope Power off Power off rack Electrical isolation Liquid isolation ---------------- ------------ ---------------- ---------------- ---------------------- ------------------ Building building yes yes no no Device device yes no no no Rack rack yes yes yes yes Room room yes yes no no Row row yes yes no no Each rule includes parameters that control automated responses: Scope: The hierarchical level (building, room, row, rack, or device) Power off: Whether to cut power to the affected scope Electrical isolation: Whether to electrically isolate the affected area Liquid isolation: Whether to close valves to isolate the affected area Minimal devices: The minimum number of affected devices required to trigger the rule Maximal devices: The maximum number of affected devices for which the rule applies These policies coordinate actions across the baseboard management controller (BMC), cluster manager, and BMS to automate responses at the configured scope. NVIDIA Mission Control tracks current leak events, historical incidents, and automated actions. Teams can access this information through command-line tools or the Base View user interface in NVIDIA Base Command Manager. The data is also exported as Prometheus metrics for integration with existing monitoring systems. How to use advanced rack management commands NVIDIA Mission Control provides rack mode commands to inspect power consumption, cooling performance, and leak detection status. These commands bring together data from liquid-cooled infrastructure to monitor conditions across racks and facilities. electricaloverview reports power consumption, power budget allocation, and electrical isolation status at the cluster or rack level liquidcoolingoverview reports supply and return temperatures, flow rates, differential pressure, and liquid isolation status at the cluster or rack level leakdetectionoverview reports leak sensor status from the BMC and BMS, isolation requests, electrical and liquid isolation status, and sensor faults at the cluster or rack level leakinfo reports current and historical leak events, including hostname, timestamp, severity, and event details, at the cluster or rack level Teams can specify a rack to inspect its status, or run the command without parameters to view status across the cluster. Historical leak events available through leakinfo can support incident investigation, pattern analysis, assessment of sensor behavior, and audit documentation. The following example uses leakinfo to query historical leak events: [a08-u04-p01-bcm-01->device]% leakinfo --history 10 Hostname Timestamp Severity Info ------------------- -------------------- ----------- ----------------- a04-p01-dgx-04-c11 2026/02/24 01:02:35 critical Chassis_0_LeakDetector_0_ColdPlate` has changed to Critical.. a05-p01-dgx-03-c05 2026/03/28 21:29:24 critical Chassis_0_LeakDetector_0_ColdPlate` has changed to Critical.. Observability integration These monitoring capabilities integrate with the NVIDIA Mission Control observability stack to provide visibility across the cluster and facility. NVIDIA Mission Control exposes the monitoring data used by its command-line tools through Prometheus endpoints, supporting prebuilt Grafana dashboards, custom dashboards, alerting rules, and integration with existing monitoring workflows and tools. Table 1 summarizes metric categories and data points to consider when building custom dashboards and alerts. Figure 4 shows a Grafana dashboard for rack cooling metrics. Get started with planning for liquid-cooled AI factories NVIDIA Mission Control integrates IT and OT systems through MQTT and configurable leak action policies to coordinate responses across trays, racks, and facilities. Shared monitoring data supports visibility into compute health and facility conditions. Watch the demo video to see the integration in action. For prerequisites and implementation steps, see the NVIDIA Mission Control Integration with Building Management System Guide. About the Authors Comments
AI NEWS JOURNAL
NVIDIA DeveloperAI NEWS / JOURNAL
Manage Liquid-Cooled AI Factories with NVIDIA Mission Control
Managing AI infrastructure such as NVIDIA Vera Rubin NVL72 requires coordinated operation of compute, power, and cooling systems. In liquid-cooled AI factories,...
번역 서비스가 일시 중지되어 원문을 표시합니다.