Skip to content
AI NEWS JOURNAL
AI NEWS / ONE EVENT. MANY PERSPECTIVES.

Responsible Quantum Machine Learning for Medical Imaging: A Fairness Audit Across Sensitive Subgroups

arXiv:2610.37819v1 Announce Type: new Abstract: Quantum machine learning (QML) is increasingly explored for medical classification, yet its behaviour under subgroup-aware fairness criteria remains understudied. We present an empirical fairness audit of classical and quantum classifiers for medical imaging, assuming QML is not inherently fair. Two scenarios are evaluated: dermatological lesions on DDI (sensitive attribute: Fitzpatrick skin type) and chest X-rays on CheXpert-derived data (sensitive attribute: age group). Using ResNet-18 embeddings, we train SVM, MLP, QSVM and QCNN under a baseline and three mitigation settings: differentiable Equalized Odds (EO) regularisation, Gradient Reversal Learning (GRL), and both combined. Foundation models (PanDerm, EVA-X) serve as external reference

Abstract:Quantum machine learning (QML) is increasingly explored for medical classification, yet its behaviour under subgroup-aware fairness criteria remains understudied. We present an empirical fairness audit of classical and quantum classifiers for medical imaging, assuming QML is not inherently fair. Two scenarios are evaluated: dermatological lesions on DDI (sensitive attribute: Fitzpatrick skin type) and chest X-rays on CheXpert-derived data (sensitive attribute: age group). Using ResNet-18 embeddings, we train SVM, MLP, QSVM and QCNN under a baseline and three mitigation settings: differentiable Equalized Odds (EO) regularisation, Gradient Reversal Learning (GRL), and both combined. Foundation models (PanDerm, EVA-X) serve as external references. Quantum classifiers may achieve competitive aggregate performance while still exhibiting subgroup disparities. Since a smaller subgroup AUC gap may stem from degrading the best group rather than improving the worst, each mitigation is also tested against a pre-specified non-inferiority margin relative to its baseline. Under this criterion, several configurations with the smallest disparity, notably QCNN with GRL on DDI, are not clinically acceptable due to loss of global discrimination. On DDI, QSVM with GRL+EO performed best and approached PanDerm in the performance/fairness trade-off; on CheXpert, QCNN with GRL achieved the highest aggregate performance but increased disparity, and EVA-X remained stronger. Fairness effects are model- and dataset-dependent, so QML requires empirical subgroup-aware evaluation. All quantum models run in classical simulation; we claim no quantum advantage.

Subjects: | Machine Learning (cs.LG); Artificial Intelligence (cs.AI); Computers and Society (cs.CY) Cite as: | arXiv:2610.37819 [cs.LG] | (or

arXiv:2610.37819v1 [cs.LG] for this version) | https://doi.org/10.48550/arXiv.2610.37819

Focus to learn more

arXiv-issued DOI via DataCite (pending registration)

Submission history

Access Paper:

View PDF

HTML (experimental)

TeX Source

Additional Features

Audio Summary

Current browse context:

References & Citations

Google Scholar

Semantic Scholar

Bookmark

Institution

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.