DIAGNOSE. VERIFY. RESOLVE. LESS GUESSING. MORE EVIDENCE. A native Windows diagnostic workstation for technicians who want evidence, not guesswork. Built by ROOKWELD · Open source · Designed for real investigations See the workstation · How it works · Get started · Safety · Field Kit An actual WPF + WebView2 Windows application. Not a browser tab. Built for the moment when "it's not working" is all you have FieldRook turns an unfamiliar Windows problem into a structured investigation. It helps a technician capture observations, run bounded diagnostics, examine traceable evidence, test competing explanations, and record whether a resolution was actually verified. The AI is an assistant to the technician—not an unrestricted shell, a source of invented facts, or an authority that can silently declare a machine fixed. The workstation A real desktop app, with a distinct identity FieldRook 0.5.0 introduces SIGNALFORGE: a retro-futuristic instrument-inspired interface, with deep plum surfaces, coral highlights, selective acid-lime signals, and restrained circuit-trace motion. Its new native WPF shell embeds the existing React workstation through WebView2 and manages the packaged local FastAPI server. The usual experience is one Windows window, not a manually launched backend plus a browser tab. The SIGNALFORGE Workbench — actual FieldRook 0.5.0 UI capture, not concept art. Examine evidence Import a Collector package Review the resolution queue Inspect the contextual evidence rail Tune the living interface Watch the real Windows app in action ▶ Watch the 33-second SIGNALFORGE release trailer (MP4) · Download v0.5.0 Real-product footage. The trailer is edited from an OS-level capture of the shipped v0.5.0 native Windows application, running isolated simulated demo investigations. Slow camera pushes, typography, transitions, and an original electronic sound bed were added in post-production; the application's UI and case data were not fabricated or altered. Decorative interface motion is not telemetry. The background motion is deliberately subtle. The interface offers Alive, Quiet, and Off preferences and supports reduced-motion behavior. Decorative activity is not presented as a real hardware measurement. From symptom to evidence Technician describes an issue │ ▼ Choose target: this PC / another PC / not yet known │ ▼ Run approved local diagnostics or import a Collector package │ ▼ Timestamped evidence + provenance + visible uncertainty │ ▼ Review hypotheses and the next useful check │ ▼ Technician observes, confirms, or supplies new evidence │ ▼ Document outcomes and export a case report What works today Important: An imported Collector package does not give FieldRook remote command execution. Host-local measurements cannot be silently substituted for a different machine, and a remote reading cannot be rechecked against the operator's own PC. The portable Collector The Collector is a separate Windows executable. It is designed to run on an affected computer without requiring a Python installation, gather selected read-only diagnostics with consent, and create a package that FieldRook can validate and import. Affected Windows PC Technician's FieldRook ┌─────────────────────┐ ┌─────────────────────┐ │ FieldRook Collector │─── evidence ZIP ────▶ │ Import + validate │ │ read-only capture │ │ investigate │ └─────────────────────┘ └─────────────────────┘ Collection is not silently uploaded. Some elevated collection categories have not yet been validated in the release candidate; permissions and unavailable measurements must be reported honestly. Get started Latest Windows desktop pre-release — v0.6.0-rc.1 (published November 3, 2026) The newest published Windows desktop package is v0.6.0-rc.1. It includes the functional Field Kit dock, Evidence Lens, and Network Lab. This is a pre-release, not a stable or independently certified build. FieldRook-0.6.0-rc.1.zip — portable Windows desktop app; extract the full archive and run FieldRook.exe. SHA256SUMS.txt — published checksums. BOM.txt — build provenance. Keep the extracted application files together. On first launch, configure the desired inference mode. Windows 10/11 x64 and WebView2 Runtime are required. The binaries are unsigned; verify the published checksums before running. No model is bundled by default, and offline evidence workflows do not depend on paid cloud inference. The v0.6.0-rc.1 release does not include a new, separately packaged Collector download. The earlier Collector build is available with v0.5.0 below; cross-version Collector compatibility has not been certified. Do not assume the older Collector is validated with v0.6.0-rc.1. For details, see the v0.6.0-rc.1 release notes and provider configuration. Previous desktop and Collector pre-release — v0.5.0 The earlier v0.5.0 release is retained for reference and includes two separately published packages: FieldRook-0.5.0.zip — previous portable desktop app. FieldRook-Collector-0.5.0.zip — portable read-only Collector. SHA256SUMS-v0.5.0.txt — release checksums. v0.5.0 does not contain the Field Kit instruments introduced in v0.6.0-rc.1. Historical native-delivery notes are in M026. Building from source This repository contains the Python/FastAPI backend, React/TypeScript frontend, native Windows shell, and packaging scripts. Development requires the corresponding build tools; end users of the packaged Desktop do not need Python or Node.js installed separately. From a Windows development checkout with Python, Node.js/pnpm, and .NET 10 SDK, follow the desktop build documentation and the M026 delivery manifest. The native shell and backend are packaged separately, then assembled into the complete distribution. Do not confuse the older browser-based development launcher with the packaged native Windows application. Safety is part of the product FieldRook deliberately makes certain operations harder to do by accident. Read-only by default. Windows diagnostics use registered capabilities and bounded inputs, not arbitrary model-authored PowerShell. Target-aware evidence. Collector imports are tied to the affected computer; mismatched identities are not silently mixed. Human control. An AI suggestion is not permission to execute it. Corrective actions require explicit approval and a registered execution path. Measured verification. An intervention being attempted or reported does not mean the problem was resolved. Local-first processing. The packaged service binds to loopback and uses application-owned local storage. Cloud-provider use requires deliberate configuration and consent. Provenance and privacy. Collector archives are integrity-checked, and diagnostic data is not automatically transmitted elsewhere. Separation of fact and inference. Model explanations and confidence language never replace measured evidence. Security documentation: FORGE privacy · Tool boundaries · Technical highlights Inside FieldRook FieldRook was developed as part of the Meta Global AI Developer Hackathon 2026. This project is independent; participation is not an endorsement by Meta. Validation and known limits For the historical v0.5.0 / M026.1 release-candidate verification (plus green GitHub Actions on the merged source), the records show: These are local release-candidate validation results, not a claim that every user environment, Windows machine, AI provider, or troubleshooting problem has been certified. Still to validate: unsigned-binary reputation and antivirus behavior across vendors; Windows machines without WebView2; multi-machine field trials; upgrade-over-existing installation; selected elevated Collector categories; lower-end CPU-only local-model responsiveness; some performance combinations on other GPUs. The Field Kit The right-hand dock is now a modular, context-aware technician toolbox. Shipped in this source tree as evidence-backed instruments with bounded diagnostics and clear local-versus-remote behavior: Evidence Lens -- deterministic before/after record compare over persisted evidence, with contradiction citations and export linkage. Network Lab -- read-only networking instrument (adapters, addresses, DNS config, resolution test) with consented re-checks and a remote-target guard. Field Kit dock -- instrument framework with pins, keyboard access, and narrow-overlay support. These instruments are included in the published v0.6.0-rc.1 desktop pre-release, and are covered by the demo scenario in M028_THREE_MINUTE_DEMO.md. They are not included in the earlier v0.5.0 binaries. The remaining modules (Process Watch, Event Decoder, Command Deck, Field Notes) are still design-prototype concepts, not shipped features. Project and development history M026 native desktop delivery Hackathon build log Provider documentation Diagnostic tool reference Security and privacy LESS GUESSING. MORE EVIDENCE. FIELDROOK · DIAGNOSE. VERIFY. RESOLVE. Made at ROOKWELD — FORGE. BUILD. IMAGINE.
AI NEWS JOURNAL
Hacker News Show HNAI NEWS / JOURNAL
Show HN: FieldRook – a local-first Windows troubleshooting workstation
Please have a look at my opensource project FieldRook, here is a short description over it.I am working as a Onsite Technichan in Sweden and i got tired of trying to puzzle togheter different windows-logs and throubleshooting steps to get forward in our tickets, and the logging started to get a real nightmare. Specially to prove for the users why it actually solved the problem and not just giving them a random "Well, it said so in the guide i read"-Type of answer.So I started building a Windowsapp that actually collects diagnostics, traceable observartions, hypothesis and verificiations. AI is a chooseble option and not something that gets direct access to run commands and such.This is a first hand version, it's currently unsigned and needs a much larger field-testing on windowsmachines. I have a hard time testing it inside our work-domain thanks to all of our security policys and such, so have mostly been running it on my local PC at home. If someone would like to have a go at it, please check out the GitHub-repo and download it and give me some feedback on what you liked and not. What worked and not.If other people that work in IT-support actually tried it, do you think it would actually help out in a day-to-day basis? What would you change in it, what is missing and how would you concider the securitymodel at the moment?Thanks in advance! Comments URL: https://news.ycombinator.com/item?id=50495476 Points: 1 # Comments: 0
翻訳サービスが停止中のため原文を表示しています。